суббота, 22 марта 2014 г.

Timer Relay,Timer Relay Manufacturers And Timer Relay Suppliers | timer-relay.com

Any Electronics is Timer Relay, IC Timer Relay, Digital Timer Relay,Super Timer Relay and Automation Products in Zhejiang China. Established in 2002
timer relay, timer relay manufacturers, timer relay suppliers, automatic timer relay

Timer Switch ,Timer Switch Manufacturer | Timer-Switch.com

Timer Switch ,Timer Switch Manufacturer and Timer Switch supplier in Zhejiang China,Established in 2002
Timer Switch, Timer Switch Manufacturer,Timer Switch Manufacturer in China,Timer Switch Manufacturers, Timer Switch Suppliers

пятница, 14 марта 2014 г.

Any Electronivd Co., Ltd. Timer switch

Any Electronivd Co., Ltd. Timer switch market is the world's largest and most professional online trading market timer switch, here we have for you a selection of the timer switch factories, manufacturers, distributors, exporters supply of information, manufacturers Yellow Pages, News , and other market conditions. Any Electronivd Co., Ltd. Was linked distributors and manufacturers, domestic and overseas electronic communication bond market is the best platform for your business engaged in procurement activities.

Timer Switch - Any Electronics Co.,Ltd.

Timer switch can be used for a variety of needs on time and automatically turns on and off electrical equipment. Widely used in enterprises, institutions and families , especially among ultraviolet disinfection bodily harm environments, such as hospitals, kindergartens , catering units , chemical sites, and containing the radiation area and avoid direct access to the interior open and close switches , frequently suffer injuries . 
At the same time switch is also particularly suitable for a variety of farms, between hatching ponds support, seat irrigation, fish tanks and other places. One operation , automatic cycle and fed a daily diet to ensure that the light irradiation time and frequency, to reduce a lot of manpower , and to avoid losses due to human error caused .
Timer switch for schools, barracks particular need . Every day more than the stipulated time , bells, bugles sounded automatically , students, military personnel as required in class, do exercise , lights out , no managers operator fatigue .
Time switch is also suitable for home , the sun rises every morning , automatic curtain slowly opened, sleep wake you ; nightfall , curtains and automatically pull together a smart home warm and wonderful all-day hold you .
Timer switch to rechargeable batteries necessary . Especially electric vehicle batteries in the entire value of the car in a very high percentage , long charging will greatly reduce battery life. Coupled with the product, which is to ensure the full capacity charging , it will not remain after the battery is fully charged is energized , the battery protection played a role greatly .
Timer switch in people's lives play an important role in people's lives brought great convenience. The main use of a reminder , plan or law of life , work . Time switches very long history , use very extensive.
From some of the ancient buildings, timers ( such as drip time, when the water droplets will lead to a certain amount authorities timekeeping ) , to modern time bomb, and today has a computer timer switch machines , etc. , have adopted a timer switch .
Examples : Lesson bell of the school is to use a timer timing , when the conditions are met ( ie, the time to reach the set point ) , the power will be turned on, so as to achieve the purpose of making bells ringing open the .

воскресенье, 28 апреля 2013 г.

24 hour timer, 7 Day Timer ATP1006-3

24 hour timer, 7 Day Timer ATP1006-3

(The time switch can be automatically
adjusted according to the latitude and longitude of the switching time.)

24 hour timer 7 Day Timer ATP1006-3
Product Name: 24 hour timer 7 Day Timer ATP1006-3
Price: $10.00

Voltage : 

1. Function and Scope

24 hour timer, 7 Day Timer ATP1006-3 (hereinafter referred
to as “time switch”) is mainly used as time control elements in the circuit
with AC frequency of 50Hz, rated control power voltage of 220V at most and DC
current of 3A at most, such as being used to regularly control switch-on and
off of street lamps, advertising light boxes and other equipments, the product
may be used to adjust the switch-on and off time everyday according to the
latitude.

The product complies with the requirements
of Standard GB 14048.5 and IEC 60947-5-1.

2. Model and Its Meaning: ATP1006-3

3. Normal Operating Condition and Installation Condition

3.1 Ambient air humidity: -5℃~+40℃, and the
average temperature is no more than +35℃ in 24h.

3.2 Altitude: no more than 2,000m.

3.3 Humidity: the relative air humidity of
the installation site shall be no more than 50% when the maximum temperature is
+40℃, while it can be higher under lower temperature. Special measures shall be
taken for the condensation occasionally formed due to temperature change.

3.4 Pollution level: 3.

3.5 In the medium with explosion hazard and
no gas that is enough to corrode metal and destroy the insulation and the place
shall not have severe conductive dust.

3.6 In the place where is provided with
anti-snow and anti-rain equipment but not be full of water steam.

3.7 In the place without significant shake,
shock and vibration.

3.8 Installation class: II.

3.9 Transport and Storage Conditions: -25℃
to +55℃.

3.10 Power voltage change scope: 85%~110%
rated operating voltage.

3.11 Protection grade: IP20.

4 Main Technical Parameters

4.1 Rated control power voltage: 50Hz
AC220V.

4.2 Conventional thermal current: Ith 16A.

4.3 Category of the control circuit: AC-15.

4.4 Rated working current (Ie):
AC-15 220V 3A.

4.5 Timing error: ≤1s/d.

4.6 Time control scope: 1min~168h.

4.7 Dimension setting range: N/S -60 ° +60 °.

4.8 Mechanical life: ≥30,000 times.

4.9 Electric endurance: ≥10,000 times.

4.10 Installation method: Device installed,
guide tracked.

4.11 Anti-interference tolerance sees Table
1.

Table
1 Anti-interference Tolerance

Item

Severity

Static
discharge tolerance

8 ×
(1±10%) KV (air discharge)

Electromagnetic
radiation tolerance

Test
field strength 10 × (1±10%) V/m

Fast
transient tolerance

For
power line: 2 × (1±10%)KV,
duration 1min

Surge
(shock) tolerance

For
power line:1 × (1±10%)KV

RF
conduction tolerance

Open
circuit test voltage 10V, frequency scope 150kHz~80MHz

Voltage
sage tolerance

Sag
30% in half a cycle, sag 60% in 5 cycles and 50 cycles, sag 100% in 250
cycles

5 Outline, Installation Dimension and
Wiring Method

5.1 Outside dimension and installation
dimension see Figure 1.

24 hour timer 7 Day Timer ATP1006-3


a) ATP1006-3 outside dimension                    b)
ATP1006-3 installation imension

Figure
1 Outside dimensions and installation dimensions of ATP1006-3

5.2 Wiring method

5.2.1 Direct control method

Power of the controlled appliance is
supplied in single-phase, of which the working current is no more than the
rated value of this switch. Direct control method may be adopted, wiring method
see Figure 2; for light load with great starting current impact, please adopt
AC contactor expansion control method.

5.2.2 Single-phase expansion method

The controlled appliance is power supplied
in single-phase, of which the working current exceeds the rated value of this
switch. Please adopt AC contactor expansion control method, see Figure 3.

5.2.3 Three-phase operating method

Power of the controlled appliance is
supplied in three-phase, so external AC contactor is required hereof.

a) The coil voltage of the controlled
contactor is AC 220C 50Hz, so its wiring method sees

Figure 4;

b) The coil voltage of the controlled contactor is AC 380V 50Hz, so
its wiring method sees

Figure 5.

24 hour timer 7 Day Timer ATP1006-3

Figure 2 Direct single-phase controlled
wiring diagram   Figure 3 Single-phase expansion controlled wiring
diagram

24 hour timer 7 Day Timer ATP1006-3

Figure 4 Three-phase controlled wiring diagram (220V
for contactor coil)   Figure 5 Three-phase controlled wiring diagram
(3800V for contactor coil)

6 Setting and Use

This product
panel is set with five buttons, namely “MD (mode)”, “R (recall)”, “24 hour timer 7 Day Timer ATP1006-3 (left)”, “24 hour timer 7 Day Timer ATP1006-3 (-)” and “24 hour timer 7 Day Timer ATP1006-3 (+)”, so it can adjust
correspondingly hour (h), minute (min) and date; if there is some operating
indication, time switch may be controlled manually or automatically.

6 Setting and Use

This product
panel is set with five buttons, namely “MD (mode)”, “R (recall)”, “24 hour timer 7 Day Timer ATP1006-3 (left)”, “24 hour timer 7 Day Timer ATP1006-3 (-)” and “24 hour timer 7 Day Timer ATP1006-3 (+)”, so it can adjust correspondingly
date (d), latitude (24 hour timer 7 Day Timer ATP1006-3),
hour (h) and minute (min), and it can also set second (sec) in clock status.

6.1 Setting
process for timing switch parameters (see Figure 6).

6.2 Setting processes are as follows:

6.2.1 Firstly power-on or press button “MD”
+ “R” to enter latitude setting interface

6.2.1.1 Current latitude and date
adjustment

6.2.1.2 Press “24 hour timer 7 Day Timer ATP1006-3”,  “24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3” to adjust latitude, for example, local
latitude 30°N shall be adjusted to “N: 30”; while local latitude 15°S shall be
adjusted to “S: 15”, see Figure 7.

24 hour timer 7 Day Timer ATP1006-3

Figure
7

6.2.1.3 Press
“MD” to enter current date adjust status, press “24 hour timer 7 Day Timer ATP1006-3” to select the adjusted position, press “24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3” to plus and minus, adjust the
display date of the product to current date, such as current March 15 shall be
set to “03: 15d”, see Figure 8. After setting, press “MD” to exit.

24 hour timer 7 Day Timer ATP1006-3

Figure 8

6.2.2 Current time adjustment

6.2.2.1 Press
button “MD” for 3s to cancel the keyboard lockout, so that “LOCK” may
disappear, the current “min” position flashes, you can press “24 hour timer 7 Day Timer ATP1006-3” to select the adjusted position
and press “24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3” to plus and minus, so
as to adjust the display time to the current time, see

Figure 9.

24 hour timer 7 Day Timer ATP1006-3

Figure
9

 

6.2.3 Timing parameters (switch-on/off
time) setting

6.2.3.1 After finish operation in 6.2.2,
press “MD” to set the timing parameters, and the corresponding position
flashes, see Figure 10.

24 hour timer 7 Day Timer ATP1006-3

Figure
10

6.2.3.2 1ON
(first switch-on) time setting: press “24 hour timer 7 Day Timer ATP1006-3”,
24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3” respectively to set 1ON
time, the latitude marks the latitude adjustment function; after setting
hour, press 24 hour timer 7 Day Timer ATP1006-3” to enter latitude mark setting
model, by then, screen does not flash, and press “24 hour timer 7 Day Timer ATP1006-3” and “24 hour timer 7 Day Timer ATP1006-3”  to switch on/off the latitude
adjustment function; after finishing this, press “MD” to enter 1OFF (first
switch-off) time setting, see Figure 11.

24 hour timer 7 Day Timer ATP1006-3

Figure 10

6.2.3.3 1OFF (first switch-off) time
setting: set 1OFF time according to steps specified in 6.2.3.2.

6.2.3.4 Continue
to press “MD”, the screen will display   “24 hour timer 7 Day Timer ATP1006-3

24 hour timer 7 Day Timer ATP1006-3

Figure
12

6.2.4 After
setting, press “MD” for 3s, enter operation state, the time switch locks
automatically, “LOCK” shows, and see Figure 13.

24 hour timer 7 Day Timer ATP1006-3

Figure
13

6.3 After locking the switch, press “MD”
and “24 hour timer 7 Day Timer ATP1006-3” at the same
time to switch manual/automatic status. Continuously press the combination, the
screen will show “OFF”, “AUTO OFF”, “ON” and “ON AUTO” successively, see Figure
14. When the circuit shall be on and off temporarily in the process of
operation, the combination buttons can be used to adjust the switch to ON and
OFF; if the time switch shall work automatically according to the set time, the
combination button shall be used to adjust the switch to “ON AUTO” or “AUTO
OFF, then the time switch may work as set time, so as to achieve automatic
control, see Figure 14.

24 hour timer 7 Day Timer ATP1006-3

Figure
14 Manual/automatic time switch setting process

7 Notes

7.1 The switch into the line can only be
connected to AC220V power supply, do not access the other power.

7.2 If you can not achieve automatic control functionCheck the lower right corner of
the screen (AUTO) is right shown?

7.3 The internal battery can only provide
the LCD screen display and settings, such as A1, A2 terminal auxiliary power
missed, is unable to drive the relay output..

7.4 If the user find errors in the productsThrough short 3, 4 terminal resetAfter reset procedures need to
set again.

7.5 If the latitude function of some group
of setting time is open, the set time may be automatically adjusted by changing
the current latitude and date, so please check once more the set time after
changing the latitude and date.

7.6 When the end of the product life,
please recycle work product or its components, for not recycled parts, please
dispose of, to protect our environment.

24 hour timer 7 Day Timer ATP1006-3






Article fro


Article from


Article from

24h Timer Switch ATP1006-2

24h Timer Switch ATP1006-2
 
(The time switch timing can be set second.)
 
1. Function and Scope
 
24h Timer Switch ATP1006-2 (hereinafter referred
to as “time switch”) is applicable for regularly controlling switch-on and off
of street lamps, advertising light boxes and other equipments in automatic
control circuit with AC frequency of 50Hz, rated control power voltage of 220V
at most and rated working current of 3A at most.
 
2. Model and Its Meaning: ATP1006-2
 
3. Normal Operating Condition and
Installation Condition
 
3.1 Ambient air humidity: -25℃~+40℃, and
the average temperature is no more than +35℃ in 24h.
 
3.2 Altitude: no more than 2,000m.
 
3.3 Humidity: the relative air humidity of
the installation site shall be no more than 50% when the maximum temperature is
+40℃, while it can be higher under lower temperature. Special measures shall be
taken for the condensation occasionally formed due to temperature change.
 
3.4 Pollution level: 3.
 
3.5 In the medium with no explosion hazard
and no gas that is enough to corrode metal and destroy the insulation and the
place shall not have severe conductive dust.
 
3.6 In the place where is provided with
anti-snow and anti-rain equipment but not be full of water steam.
 
3.7 In the place without significant shake,
shock and vibration.
 
3.8 Installation class: II.
 
3.9 Transport and Storage Conditions: -25℃
to +55℃.
 
3.10 Power voltage change scope: 85%~110%
rated voltage.
 
3.11 Protection grade: IP20.
 
4 Main Technical Parameters
 
4.1 Rated control power voltage: AC (50Hz):
220V.
 
4.2 Conventional thermal current: (Ith)16A.
 
4.3 Category of the auxiliary circuit:
AC-15.
 
4.4 Rated working current (Ie): AC-15 220V 3A.
 
4.5 Timing error: ≤1s/d.
 
4.6 Time control scope: 1sec~168h.
 
4.7 Mechanical life: ≥30,000 times.
 
4.8 Electric endurance: ≥10,000 times.
 
4.9 Installation method: Device installed,
guide tracked.
 
4.10 Anti-interference tolerance sees Table
1.
 
Table
1 Anti-interference Tolerance
 
Item
 
Severity
 
Static
discharge tolerance
 
8 ×
(1±10%) KV (air discharge)
 
Electromagnetic
radiation tolerance
 
Test
field strength 10 × (1±10%) V/m
 
Fast
transient tolerance
 
For
power line: 2 × (1±10%)KV,
duration 1min
 
Surge
(shock) tolerance
 
For
power line:1 × (1±10%)KV
 
RF
conduction tolerance
 
Open
circuit test voltage 10V, frequency scope 150kHz~80MHz
 
Voltage
sage tolerance
 
Sag
30% in half a cycle, sag 60% in 5 cycles and 50 cycles, sag 100% in 250
cycles
 
5 Outline, Installation Dimension and
Wiring Method
 
5.1 Outside dimension and installation
dimension see Figure 1.
 
 
a) ATP1006-2 outside dimension                    b)ATP1006-2
installation dimension
 
Figure
1 Outside dimensions and installation dimensions of ATP1006-2
 
5.2 Wiring method
 
5.2.1 Direct control method
 
Power of the controlled appliance is
supplied in single-phase, of which the working current is no more than the
rated value of this switch. Direct control method may be adopted, wiring method
see Figure 2; for light load with great starting current impact, please adopt
AC contactor expansion control method.
 
5.2.2 Single-phase expansion method
 
The controlled appliance is power supplied
in single-phase, of which the working current exceeds the rated value of this
switch. Please adopt AC contactor expansion control method, see Figure 3.
 
5.2.3 Three-phase operating method
 
Power of the controlled appliance is
supplied in three-phase, so external AC contactor is required hereof.
 
a) The coil voltage of the controlled
contactor is AC 220C 50Hz, so its wiring method sees
 
Figure 4;
 
b) The coil voltage of the controlled contactor is AC 380V 50Hz, so
its wiring method sees
 
Figure 5.
 
Figure 2 Direct single-phase controlled
wiring diagram   Figure 3 Single-phase expansion controlled wiring
diagram
 
Figure 4 Three-phase controlled wiring diagram (220V
for contactor coil)   Figure 5 Three-phase controlled wiring diagram
(3800V for contactor coil)
 
6 Setting and Use
 
This product
panel is set with five buttons, namely “MD (mode)”, “R (recall)”, “ (left)”, “ (-)” and “ (+)”, so it can adjust
correspondingly hour (h), minute (min) and date; if there is some operating
indication, time switch may be controlled manually or automatically.
 
6.1 Setting process for time switch
parameters (see Figure 6)
 
 
Figure 6 Time switch parameters setting process
 
6.2 Setting processes are as follows:
 
6.2.1 Press button “MD” for 3s to cancel
the keyboard lockout, so that “LOCK” may disappear, the current “date” flash,
you can adjust the date then, see Figure 7.
 
Figure
7
 
6.2.2 Current date and current time
adjustment
 
6.2.2.1 Press
buttons “” and “” respectively to adjust
date, for example, if it is Tuesday, you can adjust to “Tu”.
 
6.2.2.2 Press
“MD” to adjust the current time. Press “” to select the adjusted position and press
“” and “” to plus and minus, so
as to adjust the display time to the current time, see Figure 8.
 
Figure 8
 
6.2.3 Timing parameters (switch-on/off
time) setting
 
6.2.3.1 After finish operation 6.2.2, press
“MD” to set the timing parameters, see Figure 9.
 
Figure
9
 
6.2.3.2 1ON
(first switch-on) time setting: press “”,
“” and “” respectively to set 1ON
time and date mode, after setting, press “MD” to enter 1OFF (first
switch-off) time and date mode setting, see Figure 10.
 
Figure 10
 
6.2.3.3 1OFF (first switch-off)
time and date model setting: set 1OFF time according to steps specified
in 6.2.3.2.
 
6.2.3.4 Continue
to press “MD”, the screen will display 2ON, 2OFF … 16ON,
16OFF on the left, set switch time and date model of other groups by
referring to the above steps. For redundant time period, please press “R” to
remove the time of other groups, so that the liquid-crystal display will show “”, see Figure 11, and
then, press “R” to recall.
 
Figure
11
 
6.2.4 After
setting time of each group, press “” to set the date. By then, the screen will
show Monday to Sunday types and flash, which means the operating time are alike
from Monday to Sunday, press “” and “” to select an operating mode
suitable for the user, see Table 2.
 
Table
2 Operating Mode
 
SN
 
Operating
Mode
 
Achieved
function
 
1
 
MO  TU  WE
TH  FR  SA  SU
 
Operating time is the same every day
 
2
 
MO
TU  WE  TH  FR
SA
 
Operating
time is the same from Monday to Saturday
 
3
 
MO
TU  WE  TH  FR
 
Operating time is the same from Monday to
Friday
 
4
 
SA
SU
 
Operating
time is the same on Saturday and Sunday
 
5
 
MO
TU  WE
 
Operating
time is the same from Monday to Wednesday
 
6
 
TH
FR  SA
 
Operating
time is the same from Thursday to Saturday
 
7
 
MO
WE  FR
 
Operating
time is the same on Monday, Wednesday and Friday
 
8
 
TU
TH  SA
 
Operating
time is the same on Tuesday, Thursday and Saturday
 
9
 
MO
/ TU / WE / TH / FR / SA
/ SU
 
Operating
time is different every day
 
6.2.5 After
setting, press “MD” for 5s, enter operation state, the time switch locks
automatically, “LOCK” shows, and see Figure 12.
 
Figure
12
 
6.3 After locking the switch, press “MD”
and “” at the same
time to switch manual/automatic status. Continuously press them together, the
screen will show “AUTO OFF”, “ON”, “ON AUTO” and “OFF” successively, see Figure
13. When the circuit shall be on and off temporarily in the process of
operation, the combination buttons can be used to adjust the switch to ON and
OFF; if the time switch shall work automatically according to the set time, the
combination button shall be used to adjust the switch to “ON AUTO”, then the
time switch may work as set, so as to achieve automatic control.
 
Figure 13
 
7 Notes
 
7.1 The switch into the line can only be
connected to AC220V power supply, do not access the other power.
 
7.2 If you can not achieve automatic control function,Check the lower right corner of the screen (AUTO) is
right shown?
 
7.3 The internal battery can only provide the
LCD screen display and settings, such as A1, A2 terminal auxiliary power
missed, is unable to drive the relay output..
 
7.4 If the user find errors in the products,Through short 3, 4 terminal reset,After reset procedures need to set again.
 
7.5 When the end
of the product life, please recycle work product or its components, for not
recycled parts, please dispose of, to protect our environment.
 

суббота, 23 марта 2013 г.

Solid State Relay and SSR Relay SSR-DA DC to AC

Specifications

1.Solid State Relay and SSR Relay SSR-DA 
2.control current:5-30mA. 
3.make-on voltage:3VDC. 
4.CE 
5.2 years warranty 

Solid State Relay and SSR Relay SSR-DA DC to AC

Solid State Relay and SSR Relay SSR-DA DC to AC

Parameters of DC Solid State Relay SSR-10

Types

SSR-0/032F-20 10-40A(SSR-DD)

Name

Single-phase Solid State Relay

Control Voltage

032:3-32VDC

Control Current

6-25mA

Turn-on Voltage

5VDC

Turn-off Voltage

1VDC

Reverse Voltage

32VDC

Load Voltage

20:12-250VDC

Load Current

10A,15A,20A,25A,30A,40A

Transient Voltage

20:400VDC

On-state Voltage Drop

1.2VAC

On-off Time

≤5ms

Off-state Leakage Current

≤5mA

Dielectrics Voltage-resistance

≥2500VAC

Insulation Resistance

500mΩ 500VDC testing

Ambient temperature

-3080

Dimensions

57.2L×43.5W×29H

Work Pointer

LED

Installation

Fixed by screw

Packing

Quantity

100

Dimensions of outer case

380×215×175mm

Weight (each relay)

Approx. 110g/140g/145g

 

Solid State Relay and SSR Relay SSR-DA DC to AC

Technical specification:

1) Static dV/dt (Off-state): 100V/us.

2) Dynamic dV/dt (On-state): 20V/us.

3) On-State Voltage Drop (Max.): 2V.

4) Switching voltage for zero: 15V.

5) Isolation: 2,000Vac minimum.

6) Operating Temperature Range: -30 to 75 C

7) Turn-On Time (Max.): 10ms.

8) Turn-Off Time (Max.): 10ms.

9) Nominal frequency: 50/60Hz.